Innovative Solutions

Innovative Solutions

Packaged rooftop units
RQ Series packaged rooftop units are engineered for high efficiency and energy savings. Double-wall, rigid-polyurethane-foam-insulated cabinet construction and direct-drive backward-curved plenum fans allow quiet, energy-efficient airflow with high static-pressure capabilities. RQ units are available as air-cooled condenser packaged rooftop units, air-source, water-source, or geothermal heat pumps, 100-percent-outside-air units, and chilled-water or non-compressorized air handlers. Heating is available in high-performance hot-water, steam, electric, and gas-heating configurations. They are available in capacities from 2 to 6 tons.
AAON
2425 S. Yukon Ave.
Tulsa, Oklahoma 74107
918-583-2266
www.aaon.com

Duct liner
AP Coilflex duct liner is now available in 11/2-in. thickness. The fiber-free, elastomeric-foam duct liner is ideal for air-handling systems, variable-air-volume units, ducts, and other air-system components requiring condensation control and resistance to moisture, damage, or heat gain. AP Coilflex duct liner reduces the noise generated by fans and air movement, making it especially effective for schools, hospitals, and commercial and government buildings where good acoustics are important.
Armacell
7600 Oakwood Street Ext.
Mebane, NC 27302
919-304-3846
www.armacell.us

Commercial packaged rooftop units
WeatherExpert Series 3- to 5-ton packaged rooftop units represent Carrier’s highest-efficiency commercial packaged rooftop units ever. These ENERGY STAR-rated models meet or exceed the Consortium of Energy Efficiency rebate levels with seasonal energy-efficiency ratios of up to 17.5 and exceed the current federal minimum energy requirements by more than 34 percent.
Carrier
6304 Carrier Parkway
Syracuse, NY 13057
315-432-6000
www.carrier.com

VFD shaft-voltage test kit
The AEGIS Shaft Voltage Test Kit is designed to make measuring and documenting variable-frequency-drive- (VFD-) induced voltages easy. Motors controlled by VFDs are vulnerable to electrical bearing damage. Although specifiers may choose motors that are equipped with shaft-grounding rings, the shaft-voltage test kit may be used in retrofit applications while there still is time to head off damage and downtime. The kit includes a specially tipped probe and a portable oscilloscope.
Electro Static Technology
31 Winterbrook Road
Mechanic Falls, ME 04256
207-998-5140
www.est-static.com

Pollution-control units
Grease Grabber Triple Play and Power Play pollution-control units are designed to eliminate smoke and grease particles from commercial kitchen exhaust systems, with odor-control modules that eliminate or reduce odors to acceptable levels. The Grease Grabber Triple Play features a three-stage mechanical filter coupled with activated-carbon panels to remove odor molecules prior to discharging the air. The Grease Grabber Power Play’s permanent electrostatic collector section removes grease and smoke particles from an air stream, while its integrated self-cleaning wash sequence allows for low maintenance and constant performance.
Greenheck
P.O. Box 410
Schofield, WI 54476-0410
715-359-6171
www.greenheck.com

Ceiling-mount air conditioner
The CMW30 water-cooled, ceiling-mount air conditioner is designed for computer server rooms and other applications with dense heat loads, but where an air-cooled model cannot be used because of a lack of space. Its cooling capacity is rated at 29,400 Btuh total and 22,000 Btuh sensible. The self-contained CMW30 is only 20-in. high, enabling it to fit above a drop ceiling. No external condensing unit is necessary. The unit features an integrated energy-efficiency ratio of 17.0.
MovinCool
3900 Via Oro Ave.
Long Beach, CA 90810
800-264-9573
www.movincool.com

Air and dirt separator
Spirovent is a full-flow combination air eliminator and dirt separator for boiler and chiller systems. It uses a patented coalescing medium to provide unsurpassed efficiencies compared with centrifugal air separators and eliminates the need for side-stream filters. Spirovent eliminates routine maintenance to vent and purge, allows for a review of chemical treatment, and can result in energy reduction through improved heat transfer and reduced pump power. The units are available through 36-in. pipe size and flows of more than 30,000 gpm for both stand-alone and central-plant systems.
Spirotherm
25 N. Brandon Drive Glendale Heights, IL 60139
630-307-2662
http://www.spirotherm.com

Watertight duct smoke detectors
NEMA 4-rated InnovairFlex watertight duct smoke detectors operate in challenging conditions without the need for bulky enclosures. They can operate in airflow speeds from 100 to 4,000 fpm, temperatures from -4°F to 158°F, and humidity from 0 to 95 percent (non-condensing). They feature a watertight, UV-resistant housing that provides protection against falling dirt, rain, windblown dust, and splashing and hose-directed water.
System Sensor
3825 Ohio Ave.
St. Charles, IL 60174
630-377-6580
http://www.systemsensor.com/flex

High-efficiency commercial pump
The Viridian pump offers an 80-percent reduction in energy consumption compared with a standard commercial pump of the same size. The ECM-driven, wet-rotor Viridian features fully automated variable-speed operation, simple Web-style controls, and capacities of up to 375 gpm. An ethernet connection on the pump allows easy remote control, monitoring, and adjustment. The Viridian features a working pressure of 175 psi and is suitable for fluid temperatures from 14°F to 230°F.
Taco Inc.
1160 Cranston St.
Cranston, RI 02920
401-942-8000
www.taco-hvac.com

In-floor chilled beams
In-floor Active Chilled Beam, an energy-efficient perimeter heating and cooling solution, combines the benefits of underfloor air distribution (UFAD) with water heating and cooling efficiencies. In-floor beams provide the energy savings and capacity of an overhead chilled beam while avoiding potential damage from leaking water lines and condensation. The beams simplify UFAD design by reducing the amount of equipment under the floor and improve perimeter zone aesthetics by replacing diffusers with a linear grille.
Tate
7510 Montevideo Road
Jessup, MD 20794
800-231-7788
http://www.tateinc.com/infloorchilledbeam

Commercial Comfort Systems
York Commercial Comfort Systems (YCCS) feature factory-installed controls and factory-configured components specially designed for commercial and light commercial users. The integrated system of equipment, controls, and accessories allows nontechnical building staff to navigate, monitor, and control functions from a single intuitive user interface. Using YCCS, building owners and operators can network single-zone, constant-volume HVAC units, multiple-changeover-bypass or variable-air-volume-zoned systems, or a combination of both.
Johnson Controls Unitary Products
5757 N. Green Bay Ave.
Milwaukee, WI 53201
800-910-9675
http://www.yorkhvacdealer.com

Hide comments

Comments

  • Allowed HTML tags: <em> <strong> <blockquote> <br> <p>

Plain text

  • No HTML tags allowed.
  • Web page addresses and e-mail addresses turn into links automatically.
  • Lines and paragraphs break automatically.
Publish