Eaton Unveils PowerXL™ DM1 Micro Variable Frequency Drives

New VFD solutions help customers increase space savings in multiple environments, offer safety, efficiency, and integrated Bluetooth capabilities.
June 30, 2021
2 min read

PRESS RELEASE

PITTSBURGH PA, JUNE 29, 2021 -- Power management company Eaton today announced the launch of the PowerXL DM1 micro variable frequency drive (VFD). Made for commercial, industrial and original equipment manufacturer (OEM) customers, the Eaton engineered drive is designed to simplify design, integration and operation, improve safety and support reliable operations.

Eaton’s new VFD offers the most value in its class through onboard Ethernet-based communications, IoT, webserver, Bluetooth, safe torque off, SIL2, and more.

By providing industry-leading, onboard communications, high short-circuit current rating and compact design, Eaton’s PowerXL DM1 micro drives are engineered to help customers reduce system costs and meet the challenges of today’s more demanding commercial and industrial applications.

The PowerXL DM1 is a micro drive that incorporates a patented energy control algorithm, extensive onboard industrial communication protocols and built-in web server capabilities to help customers reduce the cost of using a VFD.

The PowerXL DM1 offering includes DM1 and DM1 Pro that increase simplicity, safety and reliability through onboard communication protocols and webserver, high short-circuit current ratings with resettable devices like breakers and manual motor protectors, and a robust design built on decades of VFD experience.

PowerXL DM1

  • 4 frame sizes  (0.5 – 25hp);
  • 230V, 480V, and 575V 3-phase models;
  • Status LEDs;
  • 1 onboard Modbus communication;
  • Bluetooth.

PowerXL DM1 Pro

  • 4 frame sizes (0.5 – 25hp);
  • 230V, 480V, and 575V 3-phase, as well as 110V and 230V 1-phase models;
  • Keypad with display;
  • Onboard STO SIL 2;
  • 5 onboard communications;
  • 4 communication cards;
  • Bluetooth.

The PowerXL DM1 drives are engineered for safety, including Bluetooth capabilities, eliminating the need for opening enclosure or panel doors to monitor the VFD, and TuV compliant Safe Torque Off (STO). The drives are tested to EN61800-9 efficiency standards and are also one of the first in the industry to achieve molded case breaker short circuit ratings within Underwriters Laboratories’ (UL) new standard 61800-5-1.

To learn more about Eaton’s VFD solutions, visit Eaton.com/DM1.

Contact

Regina Parundik, (412) 559-1614

##########

Sign up for our eNewsletters
Get the latest news and updates